Case history: DUAL HEAD HEAT EXCHANGERS - ATEX

DUAL HEAD HEAT EXCHANGERS - ATEX

DESCRIPTION

Dual head heat exchangers specially designed to reach the power required by the client in a facility in an ATEX classified area. In this specific case, a single heat exchanger with two heads was designed to reach a total capacity of 1300 KW. The installation is completed by junction boxes, mounted on the side of the heat exchanger to connect it to the single control panel by means of armoured cables designed for the power capacity. AMARC carried out complete in-house testing on this product, performing a full power test on the panel with a 2000 Volt/Ampere generator.

TECHNICAL DATA

YEAR: 2011
 
LOCATION OF THE PLANT: Gulf Area
 
FIELD OF APPLICATION: Chemical
 
PRODUCT DESCRIPTION: 1 dual head heat exchanger, rating # 300 lb
 
PROCESS DESCRIPTION: Regeneration gas
FLOW RATE: 500 kg/h
 
POWER: 1300 kW
 
OUTLET TEMPERATURE: 500°C
 
VESSEL MATERIAL: ASTM A312 TP304 L
 
DESIGN CODE: ASME VIII DIV 1